Staveley, S43

Landlord EICR in Staveley

Staveley sits inside Chesterfield borough and shares its enforcing authority, but not its housing: this is dense industrial-era terraced and ex-council stock, much of it now rented.

Chesterfield Borough Council is the enforcing authority here. The duty itself is the same everywhere in England.

Landlord

Where is the property?

The postcode tells us whether we cover you.

So we can check you are in our area
If your current report still has months to run, we would rather tell you that than book you in early.

Renting here

What letting in Staveley involves

Chesterfield Borough Council enforces here too

Staveley is within the borough, so it is the same authority as Chesterfield itself. That is worth knowing if you hold property in both, because it is one council and one set of correspondence.

Housing built for the works

Much of the older stock went up to house people working the ironworks and the pits, and it has been modernised in waves. That is the pattern that produces mixed-era wiring behind a single board.

A high rented share

Where a large part of the housing is rented, most inspections here are statutory renewals rather than one-off checks, and the renewal calendar matters more than the individual visit.

Occupied terraces and the access problem

An EICR needs the power off circuit by circuit and access to a sample of accessories. In tenanted terraces that is an access problem before it is an electrical one, and it is the most common reason a deadline slips.

Housing varies street to street, so treat this as the shortlist of questions rather than a verdict on your property.

What the law says

The duties, and the deadlines attached

England, privately rented homes. Chesterfield Borough Council enforces them in Staveley, and it is the council that can require your report within seven days of a written request.

Inspection intervalNo more than 5 years, or shorter where the report specifies
Report to existing tenantsWithin 28 days of the inspection
Report to a new tenantBefore they occupy
Report to a prospective tenantWithin 28 days of a written request
Report to the local housing authorityWithin 7 days of a written request
Remedial or further investigative workWithin 28 days, or sooner if the report specifies
Written confirmation the work is doneTo tenants and the authority within 28 days of completion
Maximum financial penalty£40,000, raised from £30,000 in 2025

Sources

This describes the law in England. The Welsh and Scottish positions differ, Scotland's repairing standard also covers portable appliances, which the England duty on private landlords does not. It is general information, not legal advice. Last checked against the primary sources on 27 August 2026.

Chesterfield Borough Council housing pages

What you get

A report records circuits, codes and limitations

The verdict is the least useful part. What matters is the schedule of test results behind it, the coded observations, and an honest record of anything the inspection could not reach.

A ticked box and nothing else is a verdict with no working shown. Worth knowing before you accept one, whoever arranged it.

Electrical Installation Condition ReportBS 7671

Schedule of circuit details

1Lighting, ground floor6A Type B
2Lighting, first floor6A Type B
3Sockets, ring final32A Type B
4Cooker32A Type B
5Immersion heater16A Type B
6Outbuilding supply20A Type B

Observations and classification codes

  • C2No RCD protection to the outbuilding supply.
  • C3Consumer unit is not of a non-combustible construction.

One C2 present, so this report reads unsatisfactory. The C3 alone would not have made it so.

An illustration, not a real report. No address, reference or signature: those belong to a real inspection.

Who does the work

Every electrician clears six checks

We do not carry out the inspection. We put you in touch with an electrician who does. An EICR is worth what the person signing it is worth, so these checks are the product. Each is verified against the issuing body's own register, not taken from a logo.

Competent to inspect and test

Inspection and testing carries its own qualification. A good installer is not automatically the right person to sign a report.

Registered with a competent person scheme

Checked on the scheme's own public register, not a badge on a website.

Public liability insurance, in date

We check the certificate and the expiry date, not just that one exists. A lapsed policy is the most common reason to turn someone away.

Reports that carry their schedule

We look at an electrician's reports before sending them a job. The schedule of results is the part worth checking.

Working to the current standard

BS 7671 as currently amended. The 2026 amendment changed what makes a report unsatisfactory, and not everyone has caught up.

A public record worth reading

We read what previous customers wrote instead of counting stars. We publish no figure of our own, because we have none.

Scheme registration and insurance details come with your quote, so you can check them against the public register yourself. How we choose electricians sets out every check, including what gets someone turned away.

Next step

Arrange a landlord EICR in Staveley

Send the address and your renewal date. If the current report has months left, we will say so instead of booking you in.

Get started

Questions

Landlord questions from Staveley

Is Staveley the same council as Chesterfield?

Yes. Staveley is within Chesterfield borough, so Chesterfield Borough Council is the enforcing authority for both.

Do I need a separate report for each property?

Yes. A report covers one installation. Several properties can often be inspected in a run, which is a scheduling question rather than a paperwork one.

Get a quote

Arrange a landlord EICR in Staveley

Address, rough circuit count, whether it is tenanted, and when the current report expires.

  • No cost, and no obligation to book anything
  • Your details are never sold on or passed around
  • A fixed price for the work described, in writing

Would rather talk it through? Leave a number in the form and say so in the details, and we will ring you rather than emailing back.

Summary of the condition of the installation
Extent of the installation coveredWhole installation, all circuits
Agreed limitationsConcealed cable, floors not lifted
Overall assessmentUnsatisfactory
Recommended next inspectionWithin 5 years

An unsatisfactory result starts a 28 day clock on a rented property. The report says what was found, so you can get it priced.

Example only. A real summary carries the property, the date and the signature.
Free quote
We call back rather than email a form letter
So we can check you are in our area
Roughly how many circuits, whether anyone is living there, and when the last inspection was

Your details are used to quote your job and nothing else. See our privacy notice.

Arrange an EICR