Scope

An EICR tests every circuit and samples the accessories

The inspection covers the fixed installation: what is wired into the building rather than plugged into it. Some of it is examined, some of it is measured, and some of it is sampled.

Step 1 of 3

Arrange an EICR

Three questions and a postcode. We match you to a qualified local electrician.

What gets tested

  • Continuity of protective conductors, so earthing is proven rather than assumed
  • Insulation resistance, which is where deteriorating cable shows up
  • Polarity, so live and neutral are where they should be
  • Earth fault loop impedance, which decides whether a fault will disconnect fast enough
  • RCD operation, tested rather than pressed

Why sampling, and not everything

Removing every accessory in a property would take days and risk damaging fittings that are perfectly sound. The inspector samples a proportion, records how many and which, and notes anything that changed their approach.

A report should tell you what the sample was. That is part of the extent of the inspection, and it is one of the things separating a real report from a quick look at the board.

Why the power goes off

Several of the tests require the circuit to be dead, so the supply is isolated circuit by circuit through the visit. The property loses power intermittently rather than all at once.

In tenanted property this is worth arranging in advance. Access and power are the two things that most often force a second visit.

Limitations are a feature, not a failure

Parts of an installation cannot be seen without taking the building apart. Concealed cable, buried joints, anything behind a fitted kitchen. A report records what could not be inspected and why.

In older or occupied property there is nearly always something. A report on a Victorian terrace with no limitations recorded is the one worth questioning.

What you get

A report records circuits, codes and limitations

The verdict is the least useful part. What matters is the schedule of test results behind it, the coded observations, and an honest record of anything the inspection could not reach.

A ticked box and nothing else is a verdict with no working shown. Worth knowing before you accept one, whoever arranged it.

Electrical Installation Condition ReportBS 7671

Schedule of circuit details

1Lighting, ground floor6A Type B
2Lighting, first floor6A Type B
3Sockets, ring final32A Type B
4Cooker32A Type B
5Immersion heater16A Type B
6Outbuilding supply20A Type B

Observations and classification codes

  • C2No RCD protection to the outbuilding supply.
  • C3Consumer unit is not of a non-combustible construction.

One C2 present, so this report reads unsatisfactory. The C3 alone would not have made it so.

An illustration, not a real report. No address, reference or signature: those belong to a real inspection.

Who does the work

Every electrician clears six checks

We do not carry out the inspection. We put you in touch with an electrician who does. An EICR is worth what the person signing it is worth, so these checks are the product. Each is verified against the issuing body's own register, not taken from a logo.

Competent to inspect and test

Inspection and testing carries its own qualification. A good installer is not automatically the right person to sign a report.

Registered with a competent person scheme

Checked on the scheme's own public register, not a badge on a website.

Public liability insurance, in date

We check the certificate and the expiry date, not just that one exists. A lapsed policy is the most common reason to turn someone away.

Reports that carry their schedule

We look at an electrician's reports before sending them a job. The schedule of results is the part worth checking.

Working to the current standard

BS 7671 as currently amended. The 2026 amendment changed what makes a report unsatisfactory, and not everyone has caught up.

A public record worth reading

We read what previous customers wrote instead of counting stars. We publish no figure of our own, because we have none.

Scheme registration and insurance details come with your quote, so you can check them against the public register yourself. How we choose electricians sets out every check, including what gets someone turned away.

Next step

Send your postcode and get a real quote

If your current report has months left, that is what you will be told.

Get started

Questions

What is checked questions

Will the electrician need to get into every room?

They need access to the consumer unit and to a sample of accessories, which in practice usually means most rooms. In an HMO or a tenanted house this is the part worth planning.

Do sockets get taken off the wall?

Some of them. Which ones and how many is a judgement the inspector records along with the extent of the inspection.

Is furniture moved?

Only what is reasonable to reach an accessory. Anything that could not be reached is recorded as a limitation rather than guessed at.

Get a quote

Arrange an EICR

Five fields. We reply with either a fixed price or the one thing we still need to know.

  • No cost, and no obligation to book anything
  • Your details are never sold on or passed around
  • A fixed price for the work described, in writing

Would rather talk it through? Leave a number in the form and say so in the details, and we will ring you rather than emailing back.

Summary of the condition of the installation
Extent of the installation coveredWhole installation, all circuits
Agreed limitationsConcealed cable, floors not lifted
Overall assessmentUnsatisfactory
Recommended next inspectionWithin 5 years

An unsatisfactory result starts a 28 day clock on a rented property. The report says what was found, so you can get it priced.

Example only. A real summary carries the property, the date and the signature.
Free quote
We call back rather than email a form letter
So we can check you are in our area
Roughly how many circuits, whether anyone is living there, and when the last inspection was

Your details are used to quote your job and nothing else. See our privacy notice.

Arrange an EICR